Temperature Sensors

Convert temperature into a measurable electrical signal.


Showing results: 616 - 618 of 618 items found.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • High Temperature Axial Torsional Extensometers (1200 C or 1600 C)

    Model 7650 - Jinan Testing Equipment IE Corporation

    Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.

  • High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)

    Model 7651 - Jinan Testing Equipment IE Corporation

    Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.